WA060 LOW TEMP HEATING PART LOAD (Antifreeze Required)

Entering Fluid Temp. (°F)
Entering Air Temp. (°F)
Total Capacity (MBtuH)
Power Input (kW)
Heat of Absortion (MBtuH)
COP
25°F 60°F 34,589 2.448 25,891 4.14
30°F 36,310 2.550 27,603 4.17
40°F 37,757 2.555 31,032 4.33
25°F 70°F 32,513 2.487 23,586 3.83
30°F 34,128 2.591 25,196 3.86
40°F 35,484 2.596 28,409 4.01
25°F 80°F 30,316 2.542 21,094 3.49
30°F 31,820 2.648 22,593 3.52
40°F 33,080 2.653 25,581 3.65