WW036 HEATING PERFORMANCE FULL LOAD

Leaving Load Fluid (°F)
Entering Source Fluid (°F)
Total Capacity (MBtuH)
Power Input (Kw)
COP
Heat Rejection (MBtuH)
100°F 35° 25,944 2.05 3.7 18,946
40° 27,568 2.04 4.0 20,601
50° 31,120 2.02 4.5 24,224
60° 35,108 2.00 5.1 28,284
70° 39,564 1.98 5.9 32,807
110°F 35° 25,726 2.33 3.2 17,769
40° 27,272 2.32 3.4 19,356
50° 30,661 2.29 3.9 22,832
60° 34,465 2.27 4.4 26,714
70° 38,730 2.25 5.0 31,060
120°F 35° 25,552 2.66 2.8 16,473
40° 27,015 2.65 3.0 17,989
50° 30,221 2.62 3.4 21,299
60° 33,834 2.59 3.8 25,013
70° 37,886 2.56 4.3 29,159
125°F 35° 25,486 2.85 2.6 15,770
40° 26,902 2.83 2.8 17,236
50° 30,013 2.80 3.1 20,465
60° 33,522 2.76 3.6 24,092
70° 37,466 2.73 4.0 28,145