WW048 HEATING PERFORMANCE PART LOAD

Leaving Load Fluid (°F)
Entering Source Fluid (°F)
Total Capacity (MBtuH)
Power Input (Kw)
COP
Heat Rejection (MBtuH)
100°F 35° 29,018 2.26 3.8 21,392
40° 30,800 2.25 4.0 23,237
50° 34,673 2.22 4.6 27,237
60° 38,981 2.20 5.2 31,709
70° 43,735 2.16 5.9 36,663
110°F 35° 28,756 2.55 3.3 20,087
40° 30,450 2.53 3.5 21,856
50° 34,155 2.51 4.0 25,701
60° 38,285 2.48 4.5 29,988
70° 42,864 2.45 5.1 34,760
120°F 35° 28,558 2.89 2.9 18,662
40° 30,164 2.87 3.1 20,355
50° 33,678 2.84 3.5 24,035
60° 37,608 2.81 3.9 28,125
70° 41,989 2.77 4.4 32,708
125°F 35° 28,506 3.09 2.7 17,915
40° 30,058 3.07 2.9 19,552
50° 33,467 3.03 3.2 23,146
60° 37,297 2.99 3.6 27,162
70° 41,556 2.96 4.1 31,606